Description

Monitors the 3Com device hardware metrics like Fan Status and Power Status.

Validated on 3Com Switch 5500G-EI 24-Port Software Version 3Com OS V3. 03.02s168p22.

SysObjID: 1.3.6.1.4.1.43.1.16.4.3.7

[A3COM-HUAWEI-LswDEVM-MIB::1.3.6.1.4.1.43.45.1.2.23.1.9]

Prerequisites

SNMP should be enabled in end device and device should support A3COM-HUAWEI-LswDEVM-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    3com.fan.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.43.45.1.2.23.1.9.1.1.1.2
    ExpressionNULL
    DescriptionIt represents the Fan status. Possible values are active (1), deactive (2) not installed (3) and unsupported (4).
    [A3COM-HUAWEI-LswDEVM-MIB::OID::1.3.6.1.4.1.43.45.1.2.23.1.9.1.1.1.1, 1.3.6.1.4.1.43.45.1.2.23.1.9.1.1.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor Name3Com Fan Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"1":"active"},{"2":"deactive"},{"3":"not-install"},{"4":"unsupport"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    3com Fan Status

    3com Fan Status

    3com.power.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.43.45.1.2.23.1.9.1.2.1.2
    ExpressionNULL
    DescriptionIt monitors the Power status. Possible values are active (1), deactive (2) not installed (3) and unsupported(4).
    [A3COM-HUAWEI-LswDEVM-MIB::OID::1.3.6.1.4.1.43.45.1.2.23.1.9.1.2.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor Name3Com Power Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"1":"active"},{"2":"deactive"},{"3":"not-install"},{"4":"unsupport"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    3com Power Status

    3com Power Status