Description

Monitors the Avtech roomalert12E internal sensor reading, switch sensors status and relay status.

Prerequisites

SNMP should be enabled in end device and device should support ROOMALERT12E-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    roomalert.12e.internal.sensor2

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.1.2.0,
    1.3.6.1.4.1.20916.1.9.1.1.6.0
    Expressioninternalsen2
    DescriptionIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage. [OIDs: 1.3.6.1.4.1.20916.1.9.1.1.2.0, 1.3.6.1.4.1.20916.1.9.1.1.6.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold100
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold105
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    roomalert.12e.switch.sensor1.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.5.1.0,
    1.3.6.1.4.1.20916.1.9.1.5.2.0
    Expressionswitchsen11
    DescriptionMonitors the status of switch sensor 1 (0 = OPEN, 1 = CLOSED). [OIDs: 1.3.6.1.4.1.20916.1.9.1.5.1.0, 1.3.6.1.4.1.20916.1.9.1.5.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"0":"OPEN"},{"1":"CLOSED"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    roomalert.12e.switch.sensor2.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.6.1.0,
    1.3.6.1.4.1.20916.1.9.1.6.2.0
    Expressionswitchsen2
    DescriptionMonitors the status of switch sensor 2 (0 = OPEN, 1 = CLOSED). [OIDs: 1.3.6.1.4.1.20916.1.9.1.6.1.0, 1.3.6.1.4.1.20916.1.9.1.6.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"0":"OPEN"},{"1":"CLOSED"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    roomalert.12e.switch.sensor3.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.7.1.0,
    1.3.6.1.4.1.20916.1.9.1.7.2.0
    Expressionswitchsen3
    DescriptionMonitors the status of switch sensor 3 (0 = OPEN, 1 = CLOSED). [OIDs: 1.3.6.1.4.1.20916.1.9.1.7.1.0, 1.3.6.1.4.1.20916.1.9.1.7.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"0":"OPEN"},{"1":"CLOSED"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    roomalert.12e.switch.sensor4.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.8.1.0,
    1.3.6.1.4.1.20916.1.9.1.8.2.0
    Expressionswitchsen4
    DescriptionMonitors the status of switch sensor 4 (0 = OPEN, 1 = CLOSED). [OIDs: 1.3.6.1.4.1.20916.1.9.1.8.1.0, 1.3.6.1.4.1.20916.1.9.1.8.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"0":"OPEN"},{"1":"CLOSED"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    roomalert.12e.relay.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.20916.1.9.1.10.1.0,
    1.3.6.1.4.1.20916.1.9.1.10.2.0
    Expressionrelay1
    DescriptionMonitors the current status of the Room Alert 12E relay output. [OIDs: 1.3.6.1.4.1.20916.1.9.1.10.1.0, 1.3.6.1.4.1.20916.1.9.1.10.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameAvtech roomalert12E Monitors
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"0":"OPEN"},{"1":"CLOSED"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph