Description
Applicable on Brocade SAN switch. Tested on a Brocade Silkworm series and VDX Series Fibre Channel Switch. Monitors the status values of temperature, fan, power supply monitors and operational status, flash operational status and SFP stats, etc. Use the Fiber Channel templates along with this template.
Prerequisites
SNMP should be enabled in end device and device should support SW-MIB OIDs and SNMP credentials should be attached against the device in portal.
How to Apply: This template is All instance selection based and Automatic select instance based. It will not ask user to select any instance (s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
system.fan.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3 |
Expression | NULL |
Description | Monitors the current status of the fan sensor. Possible values are 1- normal,2- faulty, 3- below-min, 4- nominal, 5- above-max, 6- absent. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Fan |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 2 | |
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 1,6 | [{"1":"normal"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 2,3,5 | [{"1":"normal"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
system.fan.speed
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4 |
Expression | NULL |
Description | Monitors the current value (reading) of the fan sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. [OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Fan |
Unit | rpm |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 2 | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
brocade.san.switch.operational.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.7.0, 1.3.6.1.4.1.1588.2.1.1.1.1.8.0 |
Expression | if((swAdmStatus==1),swOperStatus,0) |
Description | Monitors the current operational status of the switch. Possible operational status values are 1- Online : the switch is accessible by an external fibre channel port, 2- Offline : the switch is not accessible, 3- Testing : the switch is in a built-in test mode and is not accessible by an external fibre channel port, 4- Faulty : the switch is not operational. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.1.1.1.8] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Operational Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 2,3 | [{"1":"online"},{"2":"offline"},{"3":"testing"},{"4":"faulty"},{"0":"adminDown"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 4 | [{"1":"online"},{"2":"offline"},{"3":"testing"},{"4":"faulty"},{"0":"adminDown"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.flash.operational.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.11.0, 1.3.6.1.4.1.1588.2.1.1.1.1.12.0 |
Expression | if((swFlashDLAdmStatus==1),swFlashDLOperStatus,-1) |
Description | Monitors the flash operational status of the switch. Possible flash operational status values are 0- Unknown , 1- SW current : the flash contains the current firmware image or configuration file, 2- SW fw upgraded : the flash contains the image upgraded from the flash DL host, 3- SW Cf Uploaded : the switch configuration file has been uploaded to the host, 4- SW Cf Downloaded : the switch configuration file has been downloaded from the host, 5- SW Fw corrupted : the firmware in the flash of the switch is corrupted. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.11, 1.3.6.1.4.1.1588.2.1.1.1.1.12] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Operational Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 5 | [{"0":"unknown"},{"1":"swCurrent"},{"2":"swFwUpgraded"},{"3":"swCfUploaded"},{"4":"swCfDownloaded"},{"5":"swFwCorrupted"},{"-1":"adminDown"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.power.supply.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3 |
Expression | NULL |
Description | Monitors the current status of the power supply sensor. Possible values are 1- unknown,2- faulty, 3- below-min, 4- nominal, 5- above-max, 6- absent. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Power Supply |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 3 | |
Warning Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 1 | [{"1":"unknown"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 2,3,5 | [{"1":"unknown"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
brocade.san.switch.power.supply.value
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4 |
Expression | NULL |
Description | Monitors the current value (reading) of the power supply sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. [OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Power Supply |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 3 | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
system.temperature.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3 |
Expression | NULL |
Description | Monitors the current status of the temperature sensor. Possible values are 1- unknown,2- faulty, 3- below-min, 4- nominal, 5- above-max, 6- absent. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Temperature |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 1 | |
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 1,6 | [{"1":"unknown"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 2,3,5 | [{"1":"unknown"},{"2":"faulty"},{"3":"below-min"},{"4":"nominal"},{"5":"above-max"},{"6":"absent"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
system.temperature.value
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4 |
Expression | NULL |
Description | Monitors the current value (reading) of the temperature sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. [OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4, 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch Temperature |
Unit | C |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSensorType == 1 | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.fru.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.2.1.5.1.2 |
Expression | NULL |
Description | Monitors the current status of the FRU object in the slot. Possible values are 1- other, 2- unknown, 3- on, 4- off, 5- faulty. [OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2, 1.3.6.1.2.1.47.1.1.1.1.7] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional HA-MIB Monitors |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 2,4 | [{"1":"other"},{"2":"unknown"},{"3":"on"},{"4":"off"},{"5":"faulty"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 5 | [{"1":"other"},{"2":"unknown"},{"3":"on"},{"4":"off"},{"5":"faulty"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.cp.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.2.1.7.1.1 |
Expression | NULL |
Description | Monitors the current status of the Control Processor (CP). Possible values are 1- other, 2- unknown, 3- active, 4- standby, 5- failed. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.7.1.1] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional HA-MIB Monitors |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 2,4 | [{"1":"other"},{"2":"unknown"},{"3":"active"},{"4":"standby"},{"5":"failed"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 5 | [{"1":"other"},{"2":"unknown"},{"3":"active"},{"4":"standby"},{"5":"failed"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
brocade.switch.bp.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.2.1.8.1.1 |
Expression | NULL |
Description | Monitors the Blade Processor (BP) status. Possible values are 1- on, 2- off, 3- faulty, 4- unknown, 5- others. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.8.1.1] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional HA-MIB Monitors |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 4 | [{"1":"on"},{"2":"off"},{"3":"faulty"},{"4":"unknown"},{"5":"others"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 2,3 | [{"1":"on"},{"2":"off"},{"3":"faulty"},{"4":"unknown"},{"5":"others"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
brocade.switch.beacon.operational.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.1.18.0 |
Expression | NULL |
Description | Monitors the current operational status of the switch beacon. When the beacon is on (1), the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off (2), each LED will be in its regular status indicating color and state. [OID: 1.3.6.1.4.1.1588.2.1.1.1.1.18.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional Monitors |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 1 | [{"1":"on"},{"2":"off"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.cpu.utilization
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.26.1.0 |
Expression | NULL |
Description | Monitors the system's cpu usage. [OID: 1.3.6.1.4.1.1588.2.1.1.1.26.1.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional Monitors |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 80 | 0-100 |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 90 | 0-100 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.memory.utilization
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.26.6.0 |
Expression | NULL |
Description | Monitors the system's memory usage. [OID: 1.3.6.1.4.1.1588.2.1.1.1.26.6.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional Monitors |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 80 | 0-100 |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 90 | 0-100 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.ha.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.2.1.1.0 |
Expression | NULL |
Description | Monitors whether the system is redundant or not. Possible values are 0- redundant, 1- nonredundant. [OID: 1.3.6.1.4.1.1588.2.1.2.1.1.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch Additional Monitors |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 1 | [{"0":"redundant"},{"1":"nonredundant"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
switch.fiberchannel.port.oper.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4, 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5 |
Expression | if((swFCPortAdmStatus==1),swFCPortOpStatus,-1) |
Description | Monitors the the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent. Other possible states are 2- Offline, 3- testing, 4- faulty. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4, 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5, 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade Switch FC Port Operational Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 0,3 | [{"0":"unknown"},{"1":"online"},{"2":"offline"},{"3":"testing"},{"4":"faulty"},{"-1":"AdminstrativelyDown"}] |
Warning Repeat Count | 1 | 1-12 |
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 2,4 | [{"0":"unknown"},{"1":"online"},{"2":"offline"},{"3":"testing"},{"4":"faulty"},{"-1":"AdminstrativelyDown"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.switch.fc.port.physical.state
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3 |
Expression | NULL |
Description | This object identifies the physical state of the port: 1- No Card- no card present in this switch slot, 2- No Transceiver- no transceiver module in this port (noGbic(2) was used previously. Transceiver is the generic name for GBIC, SFP etc.), 3- Laser Fault- the module is signaling a laser fault (defective Transceiver), 4- No Light- the module is not receiving light, 5- No Sync- the module is receiving light but is out of sync, 6- In Sync- the module is receiving light and is in sync, 7- Port Fault- the port is marked faulty (defective Transceiver, cable or device), 8- DiagFault- the port failed diagnostics (defective G_Port or FL_Port card or motherboard), 9- Lock Ref- the port is locking to the reference signal. Alert is generated when the physical state is equal to 4- No Light, 7- Port Fault. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1, 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade FC Port Physical Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 6 | [{"1":"noCard"},{"2":"noTransceiver"},{"3":"laserFault"},{"4":"noLight"},{"5":"noSync"},{"6":"inSync"},{"7":"portFault"},{"8":"diagFault"},{"9":"lockRef"}] |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.sfp.current
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3 |
Expression | swSfpCurrent/1000 |
Description | Monitors the current of SFP in amps. [OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch SFP Current |
Unit | amps |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSfpCurrent Not Equals Ignore Case NA | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.sfp.rxpower
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4 |
Expression | NULL |
Description | Monitors the Rx power consumption of SFP in dBm. [OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch SFP Rx Power |
Unit | dBm |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSfpRxPower Regex match [+-]?d+.?d* | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.sfp.temperature
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.1 |
Expression | NULL |
Description | Monitors the temperature of SFP in centigrade. [OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.1] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch SFP Temperature |
Unit | C |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSfpRxPower Regex match [+-]?d+.?d* | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.sfp.txpower
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5 |
Expression | NULL |
Description | Monitors the Tx power consumption of SFP. [OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch SFP Tx Power |
Unit | dBm |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSfpTxPower Not Equals Ignore Case NA | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
brocade.san.switch.sfp.voltage
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.2 |
Expression | NULL |
Description | Monitors the voltage of SFP in millivolts. [OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Brocade SAN Switch SFP Voltage |
Unit | mV |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | 1 – 1440 (mins) |
Filter | swSfpVoltage Not Equals Ignore Case NA | |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output