Description

Monitors Cisco SB (Small Business) products main power supply status, temperature sensor status, fan status. Validated on CISCO SB switches with model : SG200, SG300 - 52 , SG300-28P, SG500X-24P.

Prerequisites

SNMP should be enabled in end device and device should support CISCOSB-HWENVIROMENT, CiscoSB-PhysicalDescription-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    cisco.sb.fan.state

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.9.6.1.101.83.1.1.1.3
    ExpressionNULL
    DescriptionProvides the mandatory state of the fan being instrumented. Possible status values are 1- Normal, 2- Warning, 3- Critical, 4- Shutdown, 5- Not Present, 6- Not Functioning. Alert is generated when status is equal to 2- Warning, 3- Critical, 4- Shutdown, 6- Not Functioning.
    [OID: 1.3.6.1.4.1.9.6.1.101.83.1.1.1.3 ].
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCisco SB Hardware - Fan
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold21-6
    Warning Repeat Count31-12
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,61-6
    Critical Repeat Count31-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    cisco.sb.power.supply.state

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.9.6.1.101.83.1.2.1.3, 1.3.6.1.4.1.9.6.1.101.83.1.2.1.4
    ExpressionrlEnvMonSupplyState
    DescriptionProvides the mandatory state of the power supply being instrumented. Possible status values are 1- Normal, 2- Warning, 3- Critical, 4- Shutdown, 5- Not Present, 6- Not Functioning. Alert is generated when status is equal to 2- Warning, 3- Critical, 4- Shutdown, 6- Not Functioning.
    [OID: 1.3.6.1.4.1.9.6.1.101.83.1.2.1.3 ]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCisco SB Hardware - Power Supply
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold21-6
    Warning Repeat Count31-12
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,61-6
    Critical Repeat Count31-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    cisco.sb.temperature.sensor.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.9.6.1.101.53.15.1.10
    ExpressionNULL
    DescriptionProvides the status value for the Sensor being instrumented.Possible status values are 1- Ok, 2- Unavailable, 3- Non Operational. Alert is generated when status is equal to 3- Non Operational.
    [OID: 1.3.6.1.4.1.9.6.1.101.53.15.1.10 ].
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCisco SB Hardware - Temperature
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold21-3
    Warning Repeat Count31-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold31-3
    Critical Repeat Count31-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph