Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    ucs.sys.equipmentfex.configstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines configstate of equipment FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"0":"un-initialized"},{"1":"un-acknowledged"},{"2":"unsupported-connectivity"},{"3":"ok"},{"4":"removing"},{"6":"ack-in-progress"},{"7":"evaluation"},{"8":"acknowledged"},{"9":"auto-ack"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.configstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines configstate of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"0":"un-initialized"},{"1":"un-acknowledged"},{"2":"unsupported-connectivity"},{"3":"ok"},{"4":"removing"},{"6":"ack-in-progress"},{"7":"evaluation"},{"8":"acknowledged"},{"9":"auto-ack"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.fsmstatus

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines fsmstatus of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold14,18[{"0":"nop"},{"1":"DynamicReallocationBegin"},{"2":"DynamicReallocationConfig"},{"3":"DynamicReallocationFail"},{"4":"DynamicReallocationSuccess"},{"5":"RemoveChassisDecomission"},{"6":"RemoveChassisDisableEndPoint"},{"7":"RemoveChassisUnIdentifyLocal"},{"8":"RemoveChassisUnIdentifyPeer"},{"9":"PsuPolicyConfigBegin"},{"10":"PsuPolicyConfigExecute"},{"11":"RemoveChassisWait"},{"12":"PsuPolicyConfigFail"},{"13":"PsuPolicyConfigSuccess"},{"14":"RemoveChassisFail"},{"15":"RemoveChassisSuccess"},{"16":"PowerCapBegin"},{"17":"PowerCapConfig"},{"18":"PowerCapFail"},{"19":"PowerCapSuccess"},{"20":"RemoveChassisBegin"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.operability

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operability state of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.operstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operstate of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.power

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines power state of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold7[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,5,9,11[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.presence

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines presence of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold40[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold11,12,20,21,22,30[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.thermal

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines thermal state of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-recoverable"},{"6":"lower-critical"},{"7":"lower-non-critical"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentiocard.voltage

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines voltage state of equipmentiocard in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-critical"},{"6":"lower-critical"},{"7":"lower-non-recoverable"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.operability

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operability state of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.operstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operstate of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.perf

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines performance of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.power

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines power state of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold7[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,5,9,11[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.presence

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines presence of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold40[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold11,12,20,21,22,30[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.thermal

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines thermal state of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-recoverable"},{"6":"lower-critical"},{"7":"lower-non-critical"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.equipmentpsu.voltage

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines voltage state of equipmentpsu in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-critical"},{"6":"lower-critical"},{"7":"lower-non-recoverable"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.operability

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operability state of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.operstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operstate of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.perf

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines performance of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.power

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines power state of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold7[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,5,9,11[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.presence

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines presence of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold40[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold11,12,20,21,22,30[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.thermal

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines thermal state of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-recoverable"},{"6":"lower-critical"},{"7":"lower-non-critical"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.fan.voltage

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines voltage state of fan in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-critical"},{"6":"lower-critical"},{"7":"lower-non-recoverable"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.licstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines license state in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4[{"0":"unknown"},{"1":"license-ok"},{"2":"license-insufficient"},{"3":"license-graceperiod"},{"4":"license-expired"},{"5":"not-applicable"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.operability

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operability state in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.operstate

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines operstate in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold51, 106[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,8,14,82,104,105,108[{"0":"unknown"},{"1":"operable"},{"2":"inoperable"},{"3":"degraded"},{"4":"powered-off"},{"5":"power-problem"},{"6":"removed"},{"7":"voltage-problem"},{"8":"thermal-problem"},{"9":"performance-problem"},{"10":"accessibility-problem"},{"11":"identity-unestablishable"},{"12":"bios-post-timeout"},{"13":"disabled"},{"14":"malformed-fru"},{"51":"fabric-conn-problem"},{"52":"fabric-unsupported-conn"},{"81":"config"},{"82":"equipment-problem"},{"83":"decomissioning"},{"84":"chassis-limit-exceeded"},{"100":"not-supported"},{"101":"discovery"},{"102":"discovery-failed"},{"103":"identify"},{"104":"post-failure"},{"105":"upgrade-problem"},{"106":"peer-comm-problem"},{"107":"auto-upgrade"},{"108":"link-activate-blocked"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.power

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines power state in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold7[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,5,9,11[{"0":"unknown"},{"1":"on"},{"2":"test"},{"3":"off"},{"4":"online"},{"5":"offline"},{"6":"offduty"},{"7":"degraded"},{"8":"power-save"},{"9":"error"},{"10":"ok"},{"11":"failed"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.presence

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines presence in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold40[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold11,12,20,21,22,30[{"0":"unknown"},{"1":"empty"},{"10":"equipped"},{"11":"missing"},{"12":"mismatch"},{"13":"equipped-not-primary"},{"20":"equipped-identity-unestablishable"},{"21":"mismatch-identity-unestablishable"},{"22":"equipped-with-malformed-fru"},{"30":"inaccessible"},{"40":"unauthorized"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.thermal

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines thermal state in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Manual
    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-recoverable"},{"6":"lower-critical"},{"7":"lower-non-critical"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    ucs.sys.equipmentfex.voltage

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionIt defines voltage state in FabricExtender
    CategoryUCS
    Collector TypeGateway
    Monitor NameCisco UCS B-Series FabricExtender Performance
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorNONE
    Warning Threshold
    Warning Repeat Count1Manual
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3,4,5,6,7[{"0":"unknown"},{"1":"ok"},{"2":"upper-non-recoverable"},{"3":"upper-critical"},{"4":"upper-non-critical"},{"5":"lower-non-critical"},{"6":"lower-critical"},{"7":"lower-non-recoverable"},{"100":"not-supported"}]
    Critical Repeat Count1Manual
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph