Description
Applicable on the Cisco UCS Standalone C-Series servers. Monitors the operational status of fan, power, storage, raid battery, chassis and memory . Tested on Cisco C-200 server.
Prerequisites
SNMP should be enabled in end device and device should support CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB, CISCO-UNIFIED-COMPUTING-STORAGE-MIB, CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB, CISCO-UNIFIED-COMPUTING-MEMORY-MIB OIDs and SNMP credentials should be attached against the device in portal.
How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | |
Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
ucs.chassis.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.7.1.27, 1.3.6.1.4.1.9.9.719.1.15.7.1.4 |
Expression | if (cucsEquipmentChassisAdminState == 1 || cucsEquipmentChassisAdminState == 2 || cucsEquipmentChassisAdminState == 5 || cucsEquipmentChassisAdminState == 7,cucsEquipmentChassisOperState,-1) |
Description | Provides the Cisco UCS equipment chassis distinguished name (DN), admin state and the operational status. Possible admin states are 1- Acknowledged, 2- Re Acknowledge , 3- Decommission, 4- Remove, 5- Enable Port Channel, 6- Disable Port Channel, 7- Auto Acknowledge. Possible equipment chassis operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.7.1.2, 1.3.6.1.4.1.9.9.719.1.15.7.1.4, 1.3.6.1.4.1.9.9.719.1.15.7.1.27] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Chassis Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107,-1 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108, -1 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.fan.module.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.13.1.7 |
Expression | NULL |
Description | Provides the Cisco UCS equipment fan module distinguished name (DN) and the operational status. Possible equipment fan module operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.13.1.2, 1.3.6.1.4.1.9.9.719.1.15.13.1.7] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Fan Module Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.fan.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.12.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS equipment fan distinguished name (DN) and the operational status. Possible equipment fan operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.12.1.2, 1.3.6.1.4.1.9.9.719.1.15.12.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Fan Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.fabric.extender.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.19.1.5, 1.3.6.1.4.1.9.9.719.1.15.19.1.21 |
Expression | if (cucsEquipmentFexAdminState == 1 || cucsEquipmentFexAdminState == 2 || cucsEquipmentFexAdminState == 5 || cucsEquipmentFexAdminState == 7,cucsEquipmentFexOperState,-1) |
Description | Provides the Cisco UCS equipment Fabric Extender (FEX) distinguished name (DN), admin state and the operational status. Possible admin states are 1- Acknowledged, 2- Re Acknowledge , 3- Decommission, 4- Remove, 5- Enable Port Channel, 6- Disable Port Channel, 7- Auto Acknowledge. Possible equipment fex operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.19.1.2, 1.3.6.1.4.1.9.9.719.1.15.19.1.5, 1.3.6.1.4.1.9.9.719.1.15.19.1.21] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS FEX Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107,-1 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108, -1 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.iocard.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.30.1.25 |
Expression | NULL |
Description | Provides the Cisco UCS equipment IOCard distinguished name (DN) and the operational status. Possible equipment IOCard operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.30.1.2, 1.3.6.1.4.1.9.9.719.1.15.30.1.25] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS IO Card Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.memory.array.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.30.1.1.11 |
Expression | NULL |
Description | Provides the Cisco UCS memory array distinguished name (DN) and the operational status. Possible memory array operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.30.1.1.2, 1.3.6.1.4.1.9.9.719.1.30.1.1.11] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Memory Array Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.memory.buffer.unit.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.30.4.1.6 |
Expression | NULL |
Description | Provides the Cisco UCS memory buffer unit distinguished name (DN) and the operational status. Possible memory buffer unit operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.30.4.1.2, 1.3.6.1.4.1.9.9.719.1.30.4.1.6] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Memory Buffer Unit Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.memory.unitstatus
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.30.11.1.13 |
Expression | NULL |
Description | Provides the Cisco UCS memory unit distinguished name (DN) and the operational status. Possible memory unit operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.30.11.1.2, 1.3.6.1.4.1.9.9.719.1.30.11.1.13] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Memory Unit Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.processor.unit.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.41.9.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS processor unit distinguished name (DN) and the operational status. Possible processor unit operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.41.9.1.2, 1.3.6.1.4.1.9.9.719.1.41.9.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Processor Unit Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.power.supply.unit.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.56.1.7 |
Expression | NULL |
Description | Provides the Cisco UCS equipment Power Supply Unit (PSU) distinguished name (DN) and the operational status. Possible equipment PSU operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.56.1.2, 1.3.6.1.4.1.9.9.719.1.15.56.1.7] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS PSU Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.storage.controller.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.45.1.1.6 |
Expression | NULL |
Description | Provides the Cisco UCS storage controller distinguished name (DN) and the operational status. Possible storage controller operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.45.1.1.2, 1.3.6.1.4.1.9.9.719.1.45.1.1.6] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Storage Controller Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.storage.local.logical.unit.number.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.45.8.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS storage local logical unit numbers (LUNs) distinguished name (DN) and the operational status. Possible storage local logical unit numbers (LUNs) operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.45.8.1.2, 1.3.6.1.4.1.9.9.719.1.45.8.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Storage Local LUNs Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.storage.logical.disk.slot.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.45.13.1.6 |
Expression | NULL |
Description | Provides the Cisco UCS storage logical disk slot distinguished name (DN) and the operational status. Possible storage logical disk slot operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.45.13.1.2, 1.3.6.1.4.1.9.9.719.1.45.13.1.6] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Storage Logical Disk Slot Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.storage.logical.disk.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.45.4.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS storage logical disk distinguished name (DN) and the operational status. Possible storage logical disk operational states are 0-Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7- Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed FRU, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.45.4.1.2, 1.3.6.1.4.1.9.9.719.1.45.4.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Storage Logical Disk Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,2,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.storage.raid.battery.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.45.11.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS storage raid battery distinguished name (DN) and the operational status. Possible storage raid battery operational states are 0- Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7-Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed Fru, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto Upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.45.11.1.2, 1.3.6.1.4.1.9.9.719.1.45.11.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Storage Raid Battery Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph
ucs.switch.card.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.9.9.719.1.15.70.1.9 |
Expression | NULL |
Description | Provides the Cisco UCS equipment switch card distinguished name (DN) and the operational status. Possible equipment switch card operational states are 0-Unknown, 1- Operable, 2- Inoperable, 3- Degraded, 4- Powered Off, 5- Power Problem, 6- Removed, 7- Voltage Problem, 8- Thermal Problem, 9- Performance Problem, 10- Accessibility Problem, 11- Identity Unestablishable, 12- Bios Post Timeout, 13- Disabled, 14- Malformed FRU, 51- Fabric Connection Problem, 52- Fabric Unsupported Connection, 81- Config, 82- Equipment Problem, 83- Decomissioning, 84- Chassis Limit Exceeded, 100- Not Supported, 101- Discovery, 102- Discovery Failed, 103- Identify, 104- Post Failure, 105- Upgrade Problem, 106- Peer Communication Problem, 107- Auto upgrade, 108- Link Activate Blocked. [OIDs: 1.3.6.1.4.1.9.9.719.1.15.70.1.2, 1.3.6.1.4.1.9.9.719.1.15.70.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Cisco UCS Switch Card Status |
Unit | None |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | NOT_IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 0,1,13,81,100,101,103,107 | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 51, 52, 81, 82, 83, 84, 100, 101, 102, 103, 104, 105, 106, 107, 108 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | No | Yes/No |
Sample Output
No graph