Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    system.fan.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3
    ExpressionNULL
    DescriptionThe mandatory state of the fan being instrumented. [OID:1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect Fan State
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold2[{"1":"Normal"},{"2":"Warning"},{"3":"Critical"},{"4":"Shutdown"},{"5":"NotPresent"},{"6":"NotFunctioning"}]
    Warning Repeat Count11-12
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,6[{"1":"Normal"},{"2":"Warning"},{"3":"Critical"},{"4":"Shutdown"},{"5":"NotPresent"},{"6":"NotFunctioning"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Fan Status

    Fan Status

    hw.dell.powerconnect.global.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.674.10895.3000.1.2.110.1.0
    ExpressionNULL
    DescriptionIndicates the current status of the Dell PowerConnect product. This is a rollup for the entire product. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible status values are 3- OK: If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure or a SW fatal error condition. 4- Non-critical: If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure or a SW fatal error condition, 5- Critical: If at least one fan is not functional, possibly causing a dangerous warming up of the device.
    [OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.1.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect Product Global Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold4[{"3":"Ok"},{"4":"Non-critical"},{"5":"Critical"}]
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold5[{"3":"Ok"},{"4":"Non-critical"},{"5":"Critical"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Global Status

    Global Status

    hw.dell.powerconnect.power.supply.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3
    ExpressionenvMonSupplyState
    DescriptionThe mandatory state of the power supply being instrumented. [OIDs: 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3, 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect Power Supply Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold2[{"1":"Normal"},{"2":"Warning"},{"3":"Critical"},{"4":"Shutdown"},{"5":"NotPresent"},{"6":"NotFunctioning"}]
    Warning Repeat Count11-12
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,4,6[{"1":"Normal"},{"2":"Warning"},{"3":"Critical"},{"4":"Shutdown"},{"5":"NotPresent"},{"6":"NotFunctioning"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    hw.dell.powerconnect.traps.flag.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.674.10895.3000.1.2.110.6.0
    ExpressionNULL
    DescriptionIndicates if this SNMP service is generating SNMP Traps. This variable can take the following values:n 1: true - The device is capable and currently configured to generate traps if necessary.n2: false - The device is not capable of generating traps.n3: disabled - The device is capable but not configured.
    [OID: 1.3.6.1.4.1.674.10895.3000.1.2.110.6.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect SNMP Trap Service Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3[{"1":"True"},{"2":"False"},{"3":"Disabled"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Dell PowerConnect Product Status Generating Traps Flag

    Dell PowerConnect Product Status Generating Traps Flag

    entity.physicalsensor.operational.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.89.83.2.1.1.1.5
    ExpressionNULL
    DescriptionProvides the operational status of the entity physical sensor. [OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.4, 1.3.6.1.4.1.89.83.2.1.1.1.5]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect Physical Sensor Operational Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2,3[{"1":"Ok"},{"2":"Unavailable"},{"3":"Nonoperational"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Entity Physical Sensor Operational Status

    Entity Physical Sensor Operational Status

    radlan.environment.fandata.temperature

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.89.83.5.1.1.2
    ExpressionNULL
    DescriptionProvides the unit temperature for Radlan environment fan data temperature. [OIDs: 1.3.6.1.4.1.89.83.2.1.1.1.1, 1.3.6.1.4.1.89.83.2.1.1.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameDell PowerConnect Radlan Fan Data Temperature
    UnitC

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold450 - 2147483647
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold500 - 2147483647
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Radlan Environment Fan Data Temperature