Description
Monitors block and RAID pools. This template is applicable for Block and RAID Pools only.
Prerequisites
Resource should be added using integration to apply storage specific templates.
How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | |
Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
emc.clariion.storagepool.availablesize
Metric Details
Applicable for | Device |
Description | Storage Pool available capacity. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list., If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | GB |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.utilization
Metric Details
Applicable for | Device |
Description | Pool Utilization. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.status
Metric Details
Applicable for | Device |
Description | Displays the information for the current state of the pool. CLARiiON have 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.rawcapacity
Metric Details
Applicable for | Device |
Description | The raw capacity of the Pool. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | GB |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.percentfree
Metric Details
Applicable for | Device |
Description | The percent of the Pool that is free. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.numberofluns
Metric Details
Applicable for | Device |
Description | The number of LUNs using the pool. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.clariion.storagepool.logicalcapacity
Metric Details
Applicable for | Device |
Description | The logical capacity of the pool. CLARiiON has 2 types of storage pools. Block pool and Raid pool. If it is block pool then command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 storagepool -list. If it is raid pool command is /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getrg |
Category | EMC CLARiiON |
Collector Type | Gateway |
Monitor Name | G2 - EMC Clariion Storage Pool Monitor |
Unit | GB |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph