Description
Monitors the storage processor instances. Applicable for storage processors.
Prerequisites
Resource should be added using integration to apply storage specific templates.
How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
emc.vnx.storageprocessor.prctbusy
Metric Details
Applicable for | Device |
Description | Indicates percent utilization of the storage processor. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 80 | 0-100 |
Warning Repeat Count | 1 | Manual | Critical Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 90 | 0-100 |
Critical Repeat Count | 1 | Manual |
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.totalthroughput
Metric Details
Applicable for | Device |
Description | Average number of requests that is passed through the storage processor per second. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | psec |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.readthroughput
Metric Details
Applicable for | Device |
Description | Average number of read requests that is passed through the storage processor per second. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | psec |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.writethroughput
Metric Details
Applicable for | Device |
Description | Average number of write requests that is passed through the storage processor per second. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | psec |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.status
Metric Details
Applicable for | Device |
Description | Status of the Storage Processor. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -spa |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.readcachestate
Metric Details
Applicable for | Device |
Description | Storage Processor Read Cache state. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.writecachestate
Metric Details
Applicable for | Device |
Description | Storage Processor Write Cache state. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.cablestatus
Metric Details
Applicable for | Device |
Description | Storage Processor Cabling status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -cablingspsa/-cablingspsb |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.vnx.storageprocessor.cpustatus
Metric Details
Applicable for | Device |
Description | Storage Processor CPU status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -cpua/-cpub |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.fanstatus
Metric Details
Applicable for | Device |
Description | Storage Processor Fan status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -fana/-fanb |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.lccstatus
Metric Details
Applicable for | Device |
Description | Storage Processor link control card status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -lcca/-lccb |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.spsstatus
Metric Details
Applicable for | Device |
Description | Storage Processor standby power supply status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -spsa/-spsb |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
emc.vnx.storageprocessor.powerstatus
Metric Details
Applicable for | Device |
Description | Storage Processor power status. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getcrus -all |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.fault-led-status
Metric Details
Applicable for | Device |
Description | Status of fault LED. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.statistics-logging-status
Metric Details
Applicable for | Device |
Description | Status of Statistics Logging. This Serve for performance monitoring. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.responsetime
Metric Details
Applicable for | Device |
Description | Amount of time it takes for a storage processor to process an input-output request. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -spnnFormula : Response time : 1000 * (Queue length/throughput) |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | ms |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.totalwrites
Metric Details
Applicable for | Device |
Description | Number of write operations performed by the storage processor. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.totalreads
Metric Details
Applicable for | Device |
Description | Number of read operations to the storage processor. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.blocksread
Metric Details
Applicable for | Device |
Description | Number of blocks transferred for read operations. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.blockswritten
Metric Details
Applicable for | Device |
Description | Number of blocks transferred for write operations. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.averagebusy-queuelength
Metric Details
Applicable for | Device |
Description | The average number of outstanding requests. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp Formula: Average Busy Queue Length: (Sum Queue Lengths - (Number arrivals With Non Zero Queue / 2)) / (Read Throughput [IO/s] + Write Throughput [IO/s]) |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.servicetime
Metric Details
Applicable for | Device |
Description | The total time spent to serve the request. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp Formula: Service time = 1000 * (Utilization/throughput) |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | ms |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
emc.vnx.storageprocessor.prctidle
Metric Details
Applicable for | Device |
Description | Indicates the percentage of time the storage processor was idle. Command: /opt/Navisphere/bin/naviseccli -h <ip-address> -User <user-name> -Password <password> -Scope 0 getall -sp |
Category | EMC VNX |
Collector Type | Gateway |
Monitor Name | G2 - EMC VNX Storage Processor Monitor |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 15 | Manual |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output