Description

Monitors the NFS data store metrics. This template is applicable for storage array.

Prerequisites

The device should be added using integrations. Gateway should be up and running. Storage Array should be reachable from Gateway. Storage Array and its resources should be in managed state.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    emc.vnxe.nfsdatastore.availablesize

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionNFS Data Store Available Size. Command is : /opt/emc/uemcli-1.5.4.1.0027/bin/uemcli.sh -d <ip-address> -port 443 -u <scope/username> -p <password> -sslPolicy accept -t 240 -noheader /stor/prov/vmware/nfs show -output csv
    CategoryEMC VNXe
    Collector TypeGateway
    Monitor NameG2 - EMC VNXe Storage Array NFS Datastore Monitor
    UnitGB

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency15Manual
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    emc.vnxe.nfsdatastore.status

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionStatus of the NFS Data store. Command is : /opt/emc/uemcli-1.5.4.1.0027/bin/uemcli.sh -d <ip-address> -port 443 -u <scope/username> -p <password> -sslPolicy accept -t 240 -noheader /stor/prov/vmware/nfs show -output csv
    CategoryEMC VNXe
    Collector TypeGateway
    Monitor NameG2 - EMC VNXe Storage Array NFS Datastore Monitor
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency15Manual
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    emc.vnxe.nfsdatastore.utilization

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionNFS Data Store Utilization. Command is : /opt/emc/uemcli-1.5.4.1.0027/bin/uemcli.sh -d <ip-address> -port 443 -u <scope/username> -p <password> -sslPolicy accept -t 240 -noheader /stor/prov/vmware/nfs show -output csv
    CategoryEMC VNXe
    Collector TypeGateway
    Monitor NameG2 - EMC VNXe Storage Array NFS Datastore Monitor
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency15Manual
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph