Description

Monitors the Cluster Array - Battery instances.

Prerequisites

Resource should be added using integration to apply storage specific templates.

How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    xtremio.cluster.bbu.ups-input

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Input
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    BBU Input

    BBU Input

    xtremio.cluster.bbu.fru-lifecycle-state

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Lifecycle State
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    BBU Lifecycle State

    BBU Lifecycle State

    xtremio.cluster.bbu.ups-conn-state

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Connection State
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    BBU Connection State

    BBU Connection State

    xtremio.cluster.bbu.ups-battery-charge-in-percent

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Charge in Percent
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Battery Charge in Percent

    Battery Charge in Percent

    xtremio.cluster.bbu.ups-load-in-percent

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Load in Percent
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    BBU Load in Percent

    BBU Load in Percent

    xtremio.cluster.bbu.ups-load-percent-level

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionBattery Load Level
    CategoryEMC XTREMIO
    Collector TypeGateway
    Monitor NameEMC Xtremio Battery Monitor
    UnitNULL

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency5Manual
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    BBU Load Level

    BBU Load Level