Description
This template monitors the storage controller enabled state, lifecycle state, node manager health state, SAS port state metrics. This template is applicable for storage array.
Prerequisites
Gateway should be up and running. Storage Array should be reachable from Gateway. Storage Array and its resources should be in managed state.
Metric Parameters
Parameter | Description |
---|---|
Frequency | |
Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
xtremio.cluster.storagecontroller.fru-lifecycle-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | Storage Controller’s FRU state, using the generic FRU transition states. |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
xtremio.cluster.storagecontroller.node-health-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | Reflects the overall health state of the Storage Controller and its contained components. |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
xtremio.cluster.storagecontroller.enabled-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | Indicates whether the Storage Controller is currently enabled or disabled, either by user or the cluster. |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
xtremio.cluster.storagecontroller.node-mgr-conn-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | Connection state between XMS and Storage Controller manager (clustering agent). |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
xtremio.cluster.storagecontroller.sas1-port-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | State of the first serial attached SCSI (SAS) port used. |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
xtremio.cluster.storagecontroller.sas2-port-state
Metric Details
Applicable for | STORAGE_ARRAY_CONTROLLER |
Description | Status of the serial attached SCSI (SAS) port 2. |
Category | EMC XTREMIO |
Collector Type | Gateway |
Monitor Name | EMC Xtremio Controller Monitor |
Unit | NULL |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | Manual |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph