Description

Applicable on HP Lefthand SAN NUS devices. Monitors the raid status and the storage device temperature.

Prerequisites

SNMP should be enabled in end device and device should support LEFTHAND-NETWORKS-NUS-COMMON-STORAGE-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance(s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    lefthand.nus.raid.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.9804.3.1.1.2.4.7.0,
    1.3.6.1.4.1.9804.3.1.1.2.4.12.0
    ExpressionstorageRaidState
    DescriptionMonitors the status of raid subsystem. Possible values are 1 - Normal 2 - Rebuilding 3 - Degraded 4 - Not rebuilding 5 - Off. [OID: 1.3.6.1.4.1.9804.3.1.1.2.4.7.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameLefthand NUS Raid Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning OperatorNOT_EQUALS_IGNORE_CASEEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning ThresholdNormal[{"1":"normal"},{"2":"rebuilding"},{"3":"degraded"},{"4":"notRebuilding"},{"5":"off"}]
    Warning Repeat Count11-12
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertYesYes/No
    Graph (Yes/No)NoYes/No

    Sample Output

    No graph

    lefthand.nus.storage.device.temperature

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3,
    1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5, 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9
    ExpressionstorageDeviceTemperature
    DescriptionMonitors the storage device temperature. [OIDs: 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.2, 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3, 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5, 1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameLefthand NUS Storage
    UnitC

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph