Description

It is applicable for HP Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines and also on HP switches meant for HP Blade systems. Monitors the rack enclosure status and status of the rack servers along with the environmental parameters like fan, power and temperature. For example, GbE2c Ethernet Blade switch.

Prerequisites

SNMP should be enabled in end device and device should support CPQRACK-MIB.mib OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    hp.proliant.rack.fan.enclosure.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.3.1.3.1.1, 1.3.6.1.4.1.232.22.2.3.1.3.1.2, 1.3.6.1.4.1.232.22.2.3.1.3.1.3, 1.3.6.1.4.1.232.22.2.3.1.3.1.11, 1.3.6.1.4.1.232.22.2.3.1.3.1.4
    ExpressioncpqRackCommonEnclosureFanCondition
    DescriptionRack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly. [OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1, 1.3.6.1.4.1.232.22.2.3.1.3.1.2, 1.3.6.1.4.1.232.22.2.3.1.3.1.3, 1.3.6.1.4.1.232.22.2.3.1.3.1.4, 1.3.6.1.4.1.232.22.2.3.1.3.1.11]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Fan Enclosure Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    rack.power.enclosure.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.3.3.1.1.1, 1.3.6.1.4.1.232.22.2.3.3.1.1.2, 1.3.6.1.4.1.232.22.2.3.3.1.1.9
    ExpressioncpqRackPowerEnclosureCondition
    DescriptionRack Power Enclosure Status. Possible values are 1- Other, 2-OK, 3- Degraded. [OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1, 1.3.6.1.4.1.232.22.2.3.3.1.1.2, 1.3.6.1.4.1.232.22.2.3.3.1.1.3, 1.3.6.1.4.1.232.22.2.3.3.1.1.9]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Power Enclosure Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold31-3
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    rack.power.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.5.1.1.1.1, 1.3.6.1.4.1.232.22.2.5.1.1.1.2, 1.3.6.1.4.1.232.22.2.5.1.1.1.3, 1.3.6.1.4.1.232.22.2.5.1.1.1.17, 1.3.6.1.4.1.232.22.2.5.1.1.1.4
    ExpressioncpqRackPowerSupplyCondition
    DescriptionPower supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system. [OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1, 1.3.6.1.4.1.232.22.2.5.1.1.1.2, 1.3.6.1.4.1.232.22.2.5.1.1.1.3, 1.3.6.1.4.1.232.22.2.5.1.1.1.4, 1.3.6.1.4.1.232.22.2.5.1.1.1.17]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Power Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    hp.proliant.rack.server.blade.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.4.1.1.1.1, 1.3.6.1.4.1.232.22.2.4.1.1.1.2, 1.3.6.1.4.1.232.22.2.4.1.1.1.3, 1.3.6.1.4.1.232.22.2.4.1.1.1.5, 1.3.6.1.4.1.232.22.2.4.1.1.1.21
    ExpressioncpqRackServerBladeStatus
    DescriptionThe health status of the blade. Possible values are 1 - Other, 2 -OK, 3 - Degraded, 4 - Failed.
    [OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1, 1.3.6.1.4.1.232.22.2.4.1.1.1.2, 1.3.6.1.4.1.232.22.2.4.1.1.1.3, 1.3.6.1.4.1.232.22.2.4.1.1.1.4, 1.3.6.1.4.1.232.22.2.4.1.1.1.5, 1.3.6.1.4.1.232.22.2.4.1.1.1.21]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Server Blade Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    hp.proliant.rack.server.temperature.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.4.3.1.1.1, 1.3.6.1.4.1.232.22.2.4.3.1.1.2, 1.3.6.1.4.1.232.22.2.4.3.1.1.3, 1.3.6.1.4.1.232.22.2.4.3.1.1.10, 1.3.6.1.4.1.232.22.2.4.3.1.1.5
    ExpressioncpqRackServerTempSensorCondition
    DescriptionThe Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system. [OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1, 1.3.6.1.4.1.232.22.2.4.3.1.1.2, 1.3.6.1.4.1.232.22.2.4.3.1.1.3, 1.3.6.1.4.1.232.22.2.4.3.1.1.4, 1.3.6.1.4.1.232.22.2.4.3.1.1.10]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Server Temperature Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    hp.proliant.rack.temperature.enclosure.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.3.1.2.1.8, 1.3.6.1.4.1.232.22.2.3.1.2.1.1, 1.3.6.1.4.1.232.22.2.3.1.2.1.2, 1.3.6.1.4.1.232.22.2.3.1.2.1.3, 1.3.6.1.4.1.232.22.2.3.1.2.1.4
    ExpressioncpqRackCommonEnclosureTempCondition
    DescriptionThe Temperature sensor status. Possible values are 1- Other, 2-OK, 3- Degraded, 4- Failed.
    [OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1, 1.3.6.1.4.1.232.22.2.3.1.2.1.2, 1.3.6.1.4.1.232.22.2.3.1.2.1.3, 1.3.6.1.4.1.232.22.2.3.1.2.1.4, 1.3.6.1.4.1.232.22.2.3.1.2.1.8]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Server Temperature Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    enclosure.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.22.2.3.1.1.1.16
    ExpressionNULL
    DescriptionThe overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. Possible values are other(1) - No temperature sensors, fans, or fuses in the enclosure or the state could no be determined. ok(2) - All temperature sensors, fans, and fuses are within the normal operating range. degraded(3) - One or more temperature sensors, fans, or fuses are outside of the normal operating range. None are failed. failed(4) - The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped. [OIDs: 1.3.6.1.4.1.232.22.2.3.1.1.1.9, 1.3.6.1.4.1.232.22.2.3.1.1.1.16]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Rack Enclosure Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorIN_LISTEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3,41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph