Description
It is applicable for HP Proliant blade systems which have the Compaq/HPs Insight Manager SNMP agents installed on either Windows or Linux machines and also on HP switches meant for HP Blade systems. Monitors the rack enclosure status and status of the rack servers along with the environmental parameters like fan, power and temperature. For example, GbE2c Ethernet Blade switch.
Prerequisites
SNMP should be enabled in end device and device should support CPQRACK-MIB.mib OIDs and SNMP credentials should be attached against the device in portal.
How to Apply: This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | |
Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
hp.proliant.rack.fan.enclosure.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.3.1.3.1.1, 1.3.6.1.4.1.232.22.2.3.1.3.1.2, 1.3.6.1.4.1.232.22.2.3.1.3.1.3, 1.3.6.1.4.1.232.22.2.3.1.3.1.11, 1.3.6.1.4.1.232.22.2.3.1.3.1.4 |
Expression | cpqRackCommonEnclosureFanCondition |
Description | Rack Fan Enclosure Status. Possible values are other(1) - Fan status detection is not supported. ok(2) - The fan is operating properly. degraded(2) - A redundant fan is not operating properly. failed(4) - A non-redundant fan is not operating properly. [OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1, 1.3.6.1.4.1.232.22.2.3.1.3.1.2, 1.3.6.1.4.1.232.22.2.3.1.3.1.3, 1.3.6.1.4.1.232.22.2.3.1.3.1.4, 1.3.6.1.4.1.232.22.2.3.1.3.1.11] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Fan Enclosure Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
rack.power.enclosure.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.3.3.1.1.1, 1.3.6.1.4.1.232.22.2.3.3.1.1.2, 1.3.6.1.4.1.232.22.2.3.3.1.1.9 |
Expression | cpqRackPowerEnclosureCondition |
Description | Rack Power Enclosure Status. Possible values are 1- Other, 2-OK, 3- Degraded. [OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1, 1.3.6.1.4.1.232.22.2.3.3.1.1.2, 1.3.6.1.4.1.232.22.2.3.3.1.1.3, 1.3.6.1.4.1.232.22.2.3.3.1.1.9] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Power Enclosure Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3 | 1-3 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
rack.power.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.5.1.1.1.1, 1.3.6.1.4.1.232.22.2.5.1.1.1.2, 1.3.6.1.4.1.232.22.2.5.1.1.1.3, 1.3.6.1.4.1.232.22.2.5.1.1.1.17, 1.3.6.1.4.1.232.22.2.5.1.1.1.4 |
Expression | cpqRackPowerSupplyCondition |
Description | Power supply status. Possible values are other(1) - The status could not be determined or not present. ok(2) - The power supply is operating normally. degraded(3) - A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) - A power supply component detects a condition that could possibly damage the system. [OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1, 1.3.6.1.4.1.232.22.2.5.1.1.1.2, 1.3.6.1.4.1.232.22.2.5.1.1.1.3, 1.3.6.1.4.1.232.22.2.5.1.1.1.4, 1.3.6.1.4.1.232.22.2.5.1.1.1.17] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Power Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
hp.proliant.rack.server.blade.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.4.1.1.1.1, 1.3.6.1.4.1.232.22.2.4.1.1.1.2, 1.3.6.1.4.1.232.22.2.4.1.1.1.3, 1.3.6.1.4.1.232.22.2.4.1.1.1.5, 1.3.6.1.4.1.232.22.2.4.1.1.1.21 |
Expression | cpqRackServerBladeStatus |
Description | The health status of the blade. Possible values are 1 - Other, 2 -OK, 3 - Degraded, 4 - Failed. [OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1, 1.3.6.1.4.1.232.22.2.4.1.1.1.2, 1.3.6.1.4.1.232.22.2.4.1.1.1.3, 1.3.6.1.4.1.232.22.2.4.1.1.1.4, 1.3.6.1.4.1.232.22.2.4.1.1.1.5, 1.3.6.1.4.1.232.22.2.4.1.1.1.21] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Server Blade Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
hp.proliant.rack.server.temperature.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.4.3.1.1.1, 1.3.6.1.4.1.232.22.2.4.3.1.1.2, 1.3.6.1.4.1.232.22.2.4.3.1.1.3, 1.3.6.1.4.1.232.22.2.4.3.1.1.10, 1.3.6.1.4.1.232.22.2.4.3.1.1.5 |
Expression | cpqRackServerTempSensorCondition |
Description | The Temperature sensor status of Rack server. Possible values are other(1) - Temperature could not be determined. ok(2) - The temperature sensor is within the normal operating range. degraded(3) - The temperature sensor is outside of the normal operating range. failed(4) - The temperature sensor detects a condition that could possibly overheat the system. [OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1, 1.3.6.1.4.1.232.22.2.4.3.1.1.2, 1.3.6.1.4.1.232.22.2.4.3.1.1.3, 1.3.6.1.4.1.232.22.2.4.3.1.1.4, 1.3.6.1.4.1.232.22.2.4.3.1.1.10] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Server Temperature Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
hp.proliant.rack.temperature.enclosure.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.3.1.2.1.8, 1.3.6.1.4.1.232.22.2.3.1.2.1.1, 1.3.6.1.4.1.232.22.2.3.1.2.1.2, 1.3.6.1.4.1.232.22.2.3.1.2.1.3, 1.3.6.1.4.1.232.22.2.3.1.2.1.4 |
Expression | cpqRackCommonEnclosureTempCondition |
Description | The Temperature sensor status. Possible values are 1- Other, 2-OK, 3- Degraded, 4- Failed. [OIDs: 1.3.6.1.4.1.232.22.2.3.1.2.1.1, 1.3.6.1.4.1.232.22.2.3.1.2.1.2, 1.3.6.1.4.1.232.22.2.3.1.2.1.3, 1.3.6.1.4.1.232.22.2.3.1.2.1.4, 1.3.6.1.4.1.232.22.2.3.1.2.1.8] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Server Temperature Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
enclosure.status
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.232.22.2.3.1.1.1.16 |
Expression | NULL |
Description | The overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. Possible values are other(1) - No temperature sensors, fans, or fuses in the enclosure or the state could no be determined. ok(2) - All temperature sensors, fans, and fuses are within the normal operating range. degraded(3) - One or more temperature sensors, fans, or fuses are outside of the normal operating range. None are failed. failed(4) - The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped. [OIDs: 1.3.6.1.4.1.232.22.2.3.1.1.1.9, 1.3.6.1.4.1.232.22.2.3.1.1.1.16] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | CPQ Rack Enclosure Status |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 5 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | IN_LIST | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 3,4 | 1-4 |
Critical Repeat Count | 1 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph