Description

This template is used for checking different health parameters of Compaq and HP Proliant Servers. Monitors CPU fan thermal health, temperature sensor health, system fans health, over server thermal health, chassis fan health, etc. It is also applicable for HP Proliant servers/blade systems which have the Compaq/HPs insight Manager SNMP agents installed on either Windows or Linux machines. Monitors the CPU and environmental parameters like fan, power and temperature across the different components in the system.

Prerequisites

SNMP should be enabled in end device and device should support CPQHLTH-MIB, CPQSTDEQ-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply:This template is All instance selection based. It will not ask user to select any instance (s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    cpu.fan.thermal.health

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.5.0
    ExpressionNULL
    DescriptionProvides the status of the processor fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver, ok(2): All fans are operating properly, failed(4): A fan is not operating properly. System will be shutdown if the failed(4) condition occurs.
    [OID: 1.3.6.1.4.1.232.6.2.6.5.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41,2,4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPU Fan Thermal Health

    CPU Fan Thermal Health

    temperature.sensors.health

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.3.0
    ExpressionNULL
    DescriptionProvides the status of the system's temperature sensors. This value will be one of the following:- other(1): Temp sensing is not supported by this system or driver, ok(2): All temp sensors are within normal operating range, degraded(3): A temp sensor is outside of normal operating range, failed(4): A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results. [OIDs: 1.3.6.1.4.1.232.6.2.6.3.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Temperature Sensor Health

    Temperature Sensor Health

    system.fans.health

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.4.0
    ExpressionNULL
    DescriptionThe status of the fan(s) in the system. This value will be one of the following:- other(1): Fan status detection is not supported by this system or driver, ok(2): All fans are operating properly, degraded(3): A non-required fan is not operating properly, failed(4): A required fan is not operating properly.
    [OID: 1.3.6.1.4.1.232.6.2.6.4.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Systems Fans Health

    Systems Fans Health

    over.server.thermal.health

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.1.0
    ExpressionNULL
    DescriptionSpecifies the overall condition of the system's thermal environment. [OID: 1.3.6.1.4.1.232.6.2.6.1.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Over Serval Thermal Health

    Over Serval Thermal Health

    hp.ilo.cpq.he.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.1.3.0
    ExpressionNULL
    DescriptionMonitors the overall status of the server health system. Possible values are 1- Other, 2- OK, 3- Degraded, 4- Failed. [OID: 1.3.6.1.4.1.232.6.1.3.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ HE Condition

    CPQ HE Condition

    hp.ilo.cpq.he.asr.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.5.17.0
    ExpressionNULL
    DescriptionMonitors the overall condition of the Automatic Server Recovery (ASR) feature. Possible values are 1- Other, 2- OK, 3- Degraded, 4- Failed. [OID: 1.3.6.1.4.1.232.6.2.5.17.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ HE ASR Condition

    CPQ HE ASR Condition

    hp.ilo.cpq.he.eventlog.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.11.2.0
    ExpressionNULL
    DescriptionMonitors the overall condition of the integrated management log feature. Possible values are 1- Other, 2- OK, 3- degraded, 4- Failed. [OID: 1.3.6.1.4.1.232.6.2.11.2.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ HE Event Log Condition

    CPQ HE Event Log Condition

    hp.ilo.cpq.he.resillent.memory.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.14.4.0
    ExpressionNULL
    DescriptionMonitors the current condition of the Advanced Memory Protection subsystem. Possible values are 1- other: The system does not support fault tolerant memory or the state cannot be determined by the Management Agent, 2- ok: This system is operating normally, 3- degraded: The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged.
    [OID: 1.3.6.1.4.1.232.6.2.14.4.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold31-3
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ HE Resilient Memory Condition

    CPQ HE Resilient Memory Condition

    cpq.ss.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.8.1.3.0
    ExpressionNULL
    DescriptionMonitors the overall condition (status) of the storage system. Possible values are 1- Other, 2- OK, 3- Degraded. [OID: 1.3.6.1.4.1.232.8.1.3.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ SS Condition

    CPQ SS Condition

    cpq.he.fault.tolerant.powersupply.condition

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.9.1.0
    ExpressionNULL
    DescriptionMonitors the overall condition of the fault tolerant power supply sub-system. Possible values are 1- Other, 2-OK, 3- Degraded, 4- Failed. [OID: 1.3.6.1.4.1.232.6.2.9.1.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Environment
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPQ HE Fault Tolerant power Supply Condition

    CPQ HE Fault Tolerant power Supply Condition

    fault.tolerant.fan.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.7.1.9, 1.3.6.1.4.1.232.6.2.6.7.1.1, 1.3.6.1.4.1.232.6.2.6.7.1.2
    ExpressioncpqHeFltTolFanCondition
    DescriptionProvides the condition of the fan. Possible values are 1- other: Fan status detection is not supported by this system or driver, 2- ok: The fan is operating properly, 3- degraded: A redundant fan is not operating properly, 4- failed: A non-redundant fan is not operating properly. [OIDs: 1.3.6.1.4.1.232.6.2.6.7.1.1, 1.3.6.1.4.1.232.6.2.6.7.1.2, 1.3.6.1.4.1.232.6.2.6.7.1.9]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Fault Tolerant Fan Health
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Fault Tolerant fan Status

    Fault Tolerant fan Status

    fault.tolerant.power.supply.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.9.3.1.2, 1.3.6.1.4.1.232.6.2.9.3.1.4, 1.3.6.1.4.1.232.6.2.9.3.1.1
    ExpressioncpqHeFltTolPowerSupplyCondition
    DescriptionMonitors the condition of the power supply. Possible values are 1- other: The status could not be determined or not present, 2- ok: The power supply is operating normally, 3- degraded: Power supply is outside of normal operating range, 4- failed: power supply component detects a condition that could permanently damage the system. [OIDs: 1.3.6.1.4.1.232.6.2.9.3.1.4, 1.3.6.1.4.1.232.6.2.9.3.1.1, 1.3.6.1.4.1.232.6.2.9.3.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Power Supply Health
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Fault Tolerant Power Supply Status

    Fault Tolerant Power Supply Status

    temperature.sensor.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.6.2.6.8.1.1, 1.3.6.1.4.1.232.6.2.6.8.1.2, 1.3.6.1.4.1.232.6.2.6.8.1.6
    ExpressioncpqHeTemperatureCondition
    DescriptionMonitors the temperature sensor condition. Possible values are 1- other: Temperature could not be determined, 2- ok: The temperature sensor is within normal operating range, 3- degraded: The temperature sensor is outside of normal operating range, 4- failed: The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results. [OIDs: 1.3.6.1.4.1.232.6.2.6.8.1.6, 1.3.6.1.4.1.232.6.2.6.8.1.1, 1.3.6.1.4.1.232.6.2.6.8.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ HE Temperature Sensor Health
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-4
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-4
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Temperature Sensor Status

    Temperature Sensor Status

    cpu.usage

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.11.2.3.1.1.3
    ExpressionNULL
    DescriptionMonitors the The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor.
    [OID: 1.3.6.1.4.1.232.11.2.3.1.1.3, 1.3.6.1.4.1.232.11.2.3.1.1.1]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ Host CPU Utilization
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold850-100
    Warning Repeat Count21-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold900-100
    Critical Repeat Count21-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    cpu.health

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.232.1.2.2.1.1.6
    ExpressionNULL
    DescriptionThe status of the processor. Possible values are 1- Unknown: The status of the CPU could not be determined, 2- OK: The CPU is functioning normally, 3- Degraded: The CPU is in a pre-failure warrantee state, 4- Failed: The CPU is in a failed state, 5- Disabled: The CPU has been disabled during power-on-self-test. [OIDs: 1.3.6.1.4.1.232.1.2.2.1.1.3, 1.3.6.1.4.1.232.1.2.2.1.1.6]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameCPQ SE CPU Status
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold31-5
    Warning Repeat Count11-12
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold41-5
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph