Description

It monitors jnx yellow alarm and jnx red alarm states.

Prerequisites

SNMP should be enabled in end device and device should support JUNIPER-ALARM-MIB OIDs and SNMP credentials should be attached against the device in portal.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    juniper.red.alarm.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.2636.3.4.2.3.1.0
    ExpressionNULL
    DescriptionThe red alarm indication on the craft interface panel. The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.3.1] - Possible values are 1: Other, 2: Off, 3: On. The critical alert will be generated if this oid value = 3(On). The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded.
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameJuniper Alarm State
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3[{"1":"other"},{"2":"off"},{"3":"on"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)NoYes/No

    Sample Output

    No graph

    juniper.yellow.alarm.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.2636.3.4.2.2.1.0
    ExpressionNULL
    DescriptionThe yellow alarm state on the craft interface panel. The yellow alarm is On when there is some system warning such as maintenance alert or significant temperature increase. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.2.1] - Possible values are 1: Other, 2: Off, 3: On. The warning alert will be generated if this oid value = 3(On). The yellow alarm is on when there is some system warning such as maintenance alert or significant temperature increase.
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameJuniper Alarm State
    UnitNone

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold3[{"1":"other"},{"2":"off"},{"3":"on"}]
    Warning Repeat Count11-12
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertYesYes/No
    Graph (Yes/No)NoYes/No

    Sample Output

    No graph