Description

It monitors Viptela hardware components temperature like PIM temperature, DRAM temperature, Board temperature, CPU Junction temperature, PEM power supply and Tray Fans speed. This Template works on Viptela vEdge physical devices (Model: vEdge-100-B).

Prerequisites

Gateway should be up and running. Viptela monitoring is performed using API. Viptela API should be reachable from Gateway.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    viptela.hardware.fan.tray0

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the tray0 fan speed in RPM
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    Unitrpm

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold3500User defined
    Warning Repeat Count11-12
    Critical OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2000User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.fan.tray1

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the tray1 fan speed in RPM
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    Unitrpm

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold3500User defined
    Warning Repeat Count11-12
    Critical OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2000User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.fan.tray2

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the tray2 fan speed in RPM
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    Unitrpm

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold3500User defined
    Warning Repeat Count11-12
    Critical OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2000User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.fan.tray3

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the tray3 fan speed in RPM
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    Unitrpm

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold3500User defined
    Warning Repeat Count11-12
    Critical OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2000User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.temp.sensors.board

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the hardware board temperature in Celsius.
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    UnitCelsius

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold60User defined
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold70User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.temp.sensors.cpu.junction

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the hardware CPU junction temperature in Celsius.
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    UnitCelsius

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold60User defined
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold70User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.temp.sensors.dram

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the hardware dram temperature in Celsius.
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    UnitCelsius

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold60User defined
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold70User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.temp.sensors.pim

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionMonitors the hardware pim temperature in Celsius.
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    UnitCelsius

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold60User defined
    Warning Repeat Count11-12
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold70User defined
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    viptela.hardware.pem.power.supply

    Metric Details

    Metric Details
    Applicable forDevice
    DescriptionProvides the power supply status. If Present and Powered On are YES and Fault is NO (Present: YES; Powered On: YES; Fault: NO) in measurement value then status is 1 otherwise 2.
    CategoryViptela
    Collector TypeGateway
    Monitor NameViptela Hardware Environment Monitor
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold21,2
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)NoYes/No

    Sample Output

    No graph