Description
Applicable on XTM fireware devices. Monitors the watch-guard system and policy statistics like CPU utilization, traffic rate, connection rate, connection drop rate and discarded packet rate.
Prerequisites
SNMP should be enabled in end device and device should support WATCHGUARD-SYSTEM-STATISTICS-MIB, WATCHGUARD-POLICY-MIB and SNMP credentials should be attached against the device in portal.
How to Apply: This template is All instance selection based. It will not ask user to select any instance(s) while assigning it to a device.
Metric Parameters
Parameter | Description |
---|---|
Frequency | Warning Threshold | If the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user. |
Critical Threshold | If the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user. |
Alert | The alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user. |
Metrics
watchguard.cpu.utilization
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.78.0 |
Expression | (wgSystemCpuUtil5)/100 |
Description | CPU utilization of the system in last 5 minutes. The value is measured in 0.01%. [OID: 1.3.6.1.4.1.3097.6.3.78.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit | % |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Warning Threshold | 80 | 0-100 |
Warning Repeat Count | 2 | 1-12 |
Critical Operator | GREATER_THAN_EQUAL | Ends with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with |
Critical Threshold | 90 | 0-100 |
Critical Repeat Count | 2 | 1-12 |
Alert | Yes | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.number.of.active.connections
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.80.0 |
Expression | NULL |
Description | Total number of currently active connections of the system. [OID: 1.3.6.1.4.1.3097.6.3.80.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.connection.request.rate
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.30.0 |
Expression | NULL |
Description | The total number of the connection requests since system is up. [OID: 1.3.6.1.4.1.3097.6.3.30.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.connection.request.drop.rate
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.34.0 |
Expression | NULL |
Description | The total number of the connection requests being dropped since system is up. [OID: 1.3.6.1.4.1.3097.6.3.34.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.traffic.in
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.9.0 |
Expression | (wgSystemTotalRecvBytes)/1000000 |
Description | The rate of total number of bytes received since system is up. This number includes both cut through traffic and host traffic. [OID: 1.3.6.1.4.1.3097.6.3.9.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit | MBps |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.traffic.out
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.6.3.8.0 |
Expression | (wgSystemTotalSendBytes)/1000000 |
Description | The rate of total number of bytes sent since system is up. This number includes both cut through traffic and host traffic. [OID: 1.3.6.1.4.1.3097.6.3.8.0] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard System Statistics |
Unit | MBps |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | ||
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.policy.traffic
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.4.2.2.1.3 |
Expression | NULL |
Description | Total traffic in bytes since setting up this policy. [OIDs: 1.3.6.1.4.1.3097.4.2.2.1.2, 1.3.6.1.4.1.3097.4.2.2.1.3] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard Policy Statistics |
Unit | Bps |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.policy.discarded.pkts
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.4.2.2.1.14 |
Expression | wgPolicyDisc*60 |
Description | Total number of packets discarded since setting up this policy. [OIDs: 1.3.6.1.4.1.3097.4.2.2.1.2, 1.3.6.1.4.1.3097.4.2.2.1.14] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard Policy Statistics |
Unit | packet/min |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph
watchguard.policy.active.conn
Metric Details
Applicable for | Device |
SNMP OID | 1.3.6.1.4.1.3097.4.2.2.1.12 |
Expression | NULL |
Description | Total number of active connections since setting up this policy. [OIDs: 1.3.6.1.4.1.3097.4.2.2.1.12, 1.3.6.1.4.1.3097.4.2.2.1.2] |
Category | SNMP monitors |
Collector Type | Gateway |
Monitor Name | Watchguard Policy Statistics |
Unit | psec |
Possible Inputs
Metric | Input Value | Range of Values |
---|---|---|
Frequency | 10 | 1 – 1440 (mins) |
Filter | NULL | Not Applicable |
Warning Operator | ||
Warning Threshold | ||
Warning Repeat Count | ||
Critical Operator | ||
Critical Threshold | ||
Critical Repeat Count | ||
Alert | No | Yes/No |
Graph (Yes/No) | Yes | Yes/No |
Sample Output
No graph