Description

Template for Yamaha Routers. Monitors include memory utilization, CPU utilization, system alarm, etc.

Prerequisites

SNMP should be enabled in end device and device should support YAMAHA-RT-HARDWARE-MIB, YAMAHA-PRODUCT-MIB and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance(s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    yamaha.router.fan.module.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.14.1.2
    ExpressionNULL
    DescriptionMonitors the status of a fan module. Possible values are 1-good, 2- noGood.
    [OIDs: 1.3.6.1.4.1.1182.2.1.14.1.1, 1.3.6.1.4.1.1182.14.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Fan Module Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"1":"good"},{"2":"notGood"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    yamaha.router.memory.utilization

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.4.0
    ExpressionNULL
    DescriptionMonitors the percentage utilization of the main memory. [OID: 1.3.6.1.4.1.1182.2.1.4.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Performance
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold900-100
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    yamaha.router.cpu.utilization.5minutes

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.7.0
    ExpressionNULL
    DescriptionMonitors the average utilization of CPU in 5 minutes. [OID: 1.3.6.1.4.1.1182.2.1.7.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Performance
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorGREATER_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold900-100
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    yamaha.router.cpu.type

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.1.0
    ExpressionNULL
    DescriptionProvides the cpu type. [OID: 1.3.6.1.4.1.1182.2.1.1.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Performance
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)NoYes/No

    Sample Output

    No graph

    yamaha.router.system.alarm

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.16.0
    ExpressionNULL
    DescriptionMonitors the condition when the alarm LED is on or off. [OID: 1.3.6.1.4.1.1182.2.1.16.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Performance
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"1":"on"},{"2":"off"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    yamaha.router.inbox.temperature

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.15.0
    ExpressionNULL
    DescriptionMonitors the temperature in the box. [OID: 1.3.6.1.4.1.1182.2.1.15.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Performance
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph

    yamaha.router.power.module.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1182.2.1.13.1.2
    ExpressionNULL
    DescriptionMonitors the status of a power module. Possible values are 1- up, 2- down, 3- notInstalled.
    [OIDs: 1.3.6.1.4.1.1182.2.1.13.1.1, 1.3.6.1.4.1.1182.13.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameYamaha Router Power Module Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency151 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"1":"up"},{"2":"down"},{"3":"notInstalled"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    No graph